{"product_id":"ilda-767","title":"ILDA-767 6 in 1 Combo Multi-function CO2 \u0026 CO \u0026 Temperature, Humidity RH %, DP, WB, USB Data Logger with Software, Meter IAQ Tester","description":"\u003cp\u003eThe portable CO2 meter uses NDIR (non-dispersive infrared) technology to ensure reliability and long term stability. It's useful in verifying HVAC system performance and air ventilation control.\u003c\/p\u003e\n\u003cp\u003ePoor indoor air quality is considered unhealthy because it causes tiredness, loss of ability to concentrate, and even illness (ex. Sick Building Syndrome). IAQ monitoring and survey, especially on CO2 level and air ventilation become widely applied in public areas such as offices, classrooms, factories hospitals, and hotels. It also suggested regulations of industrial in some countries.\u003c\/p\u003e\n\u003cp\u003eCarbon monoxide is a colorless, odorless, and tasteless gas which is slightly lighter than air. It is highly toxic to humans and animals.\u003c\/p\u003e\n\u003cp style=\"font-weight: bold; margin-bottom: 5px !important;\"\u003eFeatures:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBig LCD display with blue backlight to use in dark area\u003c\/li\u003e\n\u003cli\u003eOne-touch to display CO2 \/ Dew point temperature \/ Wet bulb temperature \/ Air temperature \/ Humidity \/ CO in turns.\u003c\/li\u003e\n\u003cli\u003eDesigned with NDIR ( non-dispersive infrared ) Waveguide technology CO2 sensor\u003c\/li\u003e\n\u003cli\u003eProgrammable warning CO level\u003c\/li\u003e\n\u003cli\u003eLong time drift compensation on CO2 sensor\u003c\/li\u003e\n\u003cli\u003eAudible alarm (~80db) threshold setting\u003c\/li\u003e\n\u003cli\u003eMax, Min, TWA, STEL functions included\u003c\/li\u003e\n\u003cli\u003eMini USB for PC download function for analysis\u003c\/li\u003e\n\u003cli\u003e99 points manually recording\u003c\/li\u003e\n\u003cli\u003e32000\/24000 points auto recording\u003c\/li\u003e\n\u003cli\u003eReview 99 points manual record\u003c\/li\u003e\n\u003cli\u003eHold function freezes current readings\u003c\/li\u003e\n\u003cli\u003eHousing design surrounds with rails to help Air ventilation for quick \u0026amp; accurate response\u003c\/li\u003e\n\u003cli\u003eEasy to manually calibrate C02 at fresh air around 380-420ppm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp style=\"font-weight: bold; margin-bottom: 5px !important;\"\u003eSpecifications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeasuring Range:\n\u003cul\u003e\n\u003cli\u003eCO2: 0~9999ppm\n\u003cul\u003e\n\u003cli\u003e(5001~9999 out of scale)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eCO: 0~1000 ppm\u003c\/li\u003e\n\u003cli\u003eTemperature : -20 ~ 60°C (-5~140°F)\u003c\/li\u003e\n\u003cli\u003eRelative Humidity : 0.1%~99.9%RH\u003c\/li\u003e\n\u003cli\u003eDP (Dew Point temp.) : -20.0~59.9°C\u003c\/li\u003e\n\u003cli\u003eWB (Wet bulb temp.) : -5.0~59.9°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eResolution: 1ppm, 0.1°C\/°F, 0.1%RH\u003c\/li\u003e\n\u003cli\u003eAccuracy:\n\u003cul\u003e\n\u003cli\u003eCO2: ±30ppm ±5% of reading ( 0~5000ppm), other ranges are not specified\u003c\/li\u003e\n\u003cli\u003eCO: +\/-10ppm for les than 100ppm\n\u003cul\u003e\n\u003cli\u003e+\/-10% or reading for 101~500ppm\u003c\/li\u003e\n\u003cli\u003e+\/-20% of reading for 501ppm and above\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eTemperature: ±0.6°C \/ ±0.9°F\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: ±3%RH (at 25°C, 10-90%RH); ±5%RH (at 25°C, other range)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eCO2 warm-up time : 30 seconds\u003c\/li\u003e\n\u003cli\u003eResponse time\n\u003cul\u003e\n\u003cli\u003eCO2: \u0026lt;30 seconds (90% step change)\u003c\/li\u003e\n\u003cli\u003eCO: \u0026lt;60 seconds (90% step change)\u003c\/li\u003e\n\u003cli\u003eTemp.: \u0026lt;2 mins (90% step change)\u003c\/li\u003e\n\u003cli\u003eRH: \u0026lt;10 mins (90% step change)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eLCD size: 26mm(H) x 44mm(L), 205mm(L) x 70(W) x 56(H)\u003c\/li\u003e\n\u003cli\u003eOperating condition : -20 to 50°C (C02 sensor), 0 to 50°C (CO sensor)\n\u003cul\u003e\n\u003cli\u003e(Avoid condensation) -20 to 60°C (for the rest parameters)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eStorage condition: -20~60°C , 10~90%RH (avoid condensation)\u003c\/li\u003e\n\u003cli\u003ePower supply: AA x 4pcs (included) or 9V adaptor (not included)\u003c\/li\u003e\n\u003cli\u003eBattery life: \u0026gt;24 hours (alkaline battery)\u003c\/li\u003e\n\u003cli\u003eWeight: 200g\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp style=\"font-weight: bold; margin-bottom: 5px !important;\"\u003eSet Includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1x 6-in-1 IAQ Meter\u003c\/li\u003e\n\u003cli\u003e4x AA battery\u003c\/li\u003e\n\u003cli\u003e1x English Manual\u003c\/li\u003e\n\u003cli\u003e1x USB cable\u003c\/li\u003e\n\u003cli\u003e1x CD software\u003c\/li\u003e\n\u003cli\u003e1x Carrying case\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"A01","offers":[{"title":"Default Title","offer_id":43067195523115,"sku":"ILDA-767","price":418.9,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0662\/5850\/1675\/files\/gain-express-77597-77597-6-in-1-combo-multi-function-co2-co-temperature-humidity-rh-dp-wb-usb-data-logger-with-software-meter-iaq-tester-134382.jpg?v=1770633970","url":"https:\/\/instrulife.com\/products\/ilda-767","provider":"Instrulife","version":"1.0","type":"link"}